Navien Boilers and Combi-Boilers Prices

GSHA Services, LTD installs and services Navien combi-boilers and heating boilers in McHenry County and Lake County, Illinois, and the surrounding Chicago suburbs and southeastern Wisconsin. GSHA is a Navien Service Specialist (NSS) and an authorized Navien dealer listed on Navien’s installer locator at navieninc.com, with Navien Level 3 trained technicians handling sizing, installation, start-up and annual service.

The Navien boiler prices on this page are complete installed packages, not equipment-only figures. Navien NHB-H and NFB-H heating boilers are installed from $8,211.42, and NCB-H and NFC-H combi-boilers from $10,342.85. Estimates are free.

Request a free estimate Call (224) 220-3660

Navien NCB-240/110H combi-boiler installed by GSHA Services, LTD in Woodstock, IL
A Navien NCB-240/110H combi-boiler installed by GSHA Services in Woodstock, IL (February 2026).

Combi-boiler

Heat and hot water from one wall-hung unit. NCB-H (5 sizes) and NFC-H fire-tube (2 sizes).

Installed from $10,342.85

Compare combi-boilers

Heating-only boiler

For radiators, baseboard and radiant floors, with your existing water heater or an indirect tank. NHB-H (4 sizes) and NFB-H (2 sizes).

Installed from $8,211.42

Compare boilers

NPF hydro furnace

A 97% AFUE condensing furnace for homes with ductwork, with a modulating burner and variable-speed blower.

Package from $5,993.38

See NPF models

Combi-boiler or heating-only boiler?

A combi-boiler is one wall-hung unit that does two jobs: it heats your home through radiators, baseboard or in-floor tubing, and it makes domestic hot water on demand for showers, sinks and laundry. It replaces a separate boiler and water heater, which frees up floor space and means only one gas appliance to maintain. Navien’s NCB-H and NFC-H combi-boilers suit single-family homes with hydronic heat that also want endless hot water without a storage tank.

A heating-only boiler, such as the Navien NHB-H or NFB-H, does the space-heating job alone. It is the right choice when you already have a water heater you plan to keep, when you want to pair the boiler with an indirect tank for very high hot-water demand, or when the heating load is large. Heating-only boilers also carry a longer Navien heat-exchanger warranty than the combi models (NHB-H: 10 years, then pro-rated through year 15; NFB-H: 12 years, then pro-rated through year 15; combi-boilers: 10 years). Parts coverage is 5 years on all of them.

Navien also makes the NPF hydro furnace for homes with ductwork: its own condensing gas burner heats water in a sealed internal loop, and a variable-speed blower moves warm air across a coil into the ducts. The three NPF models GSHA installs are listed in the NPF hydro furnace section below.

Two ratings you will see below: AFUE is the heating efficiency rating (higher is better), and the turndown ratio is how low the burner can modulate below full fire, which reduces short cycling and keeps room temperatures steadier. All of these Navien models are condensing appliances: a second heat exchanger captures heat from the exhaust, which is why efficiency is high and why they vent in PVC and need a condensate drain.

Navien NCB-H and NFC-H combi-boilers

The second number in the model name is the heating input in thousands of BTU/h (an NCB-240/110H heats at up to 110,000 BTU/h); the first number is the hot-water size class, and the table shows the actual hot-water rating. Sizing matters in a Midwest winter because incoming water is cold: a 70°F temperature rise is a realistic winter number, and the gallons per minute (GPM) at that rise tells you how many fixtures can run at the same time. All seven models are 95% AFUE, ENERGY STAR certified, indoor wall-hung, and modulate down to 15:1 on domestic hot water.

ModelHeating input (max)DHW input (max)DHW flow (Navien)Heating turndownAFUEInstalled package price
NCB-190/060H60,000 BTU/h160,000 BTU/h6.4 GPM at 45°F rise; 4.1 GPM at 70°F5.5:195%$10,401.19
NCB-190/080H80,000 BTU/h160,000 BTU/h6.4 GPM at 45°F rise; 4.1 GPM at 70°F7.3:195%$10,401.19
NCB-240/110H110,000 BTU/h199,900 BTU/h7.9 GPM at 45°F rise; 5.1 GPM at 70°F8.5:195%$10,342.85
NCB-240/130H130,000 BTU/h199,900 BTU/h7.9 GPM at 45°F rise; 5.1 GPM at 70°F10:195%$10,531.91
NCB-250/150H150,000 BTU/h210,000 BTU/h8.4 GPM at 45°F rise; 5.4 GPM at 70°F11:195%$10,730.70
NFC-250/175H175,000 BTU/h210,000 BTU/h8.4 GPM at 45°F rise; 5.4 GPM at 70°F13:195%$10,948.71
NFC-250/200H199,900 BTU/h210,000 BTU/h8.4 GPM at 45°F rise; 5.4 GPM at 70°F15:195%$11,136.53

Specifications are from Navien’s official model and series pages; prices are GSHA installed packages (see what is included below). Navien’s flow tables run down to a 0.5 GPM minimum flow, and actual flow depends on incoming water temperature.

What separates the NFC-H from the NCB-H. The NCB-H uses Navien’s dual condensing stainless steel heat exchangers plus a separate stainless flat-plate exchanger for domestic hot water, and tops out at 150,000 BTU/h of heating. The NFC-H uses an ASME-certified stainless steel fire tube heat exchanger, which lets it reach 175,000 or 199,900 BTU/h of heating with a 13:1 or 15:1 heating turndown, while keeping the same 210,000 BTU/h hot-water capacity as the largest NCB-H. The NFC-H cabinet is about 4 in. taller, 4.5 in. deeper and 45 to 54 lbs heavier than an NCB-H, so wall space and mounting matter. Choose an NFC-H when the heating load is too large for an NCB-H.

Both series have built-in powered connections for three zone pumps or three zone valves. Navien lists these optional add-ons for the NCB-H and NFC-H series: NaviLink Wi-Fi control ($288.43) or NaviLink Lite ($153.55) for app control and alerts, and the NaviCirc valve ($99.60), which recirculates hot water through your existing pipes to cut wait time at distant fixtures when there is no dedicated return line. NaviCirc needs a separate recirculation pump, which we price on the estimate; accessory prices are confirmed on your written estimate.

Navien wall-hung condensing boiler with multi-zone circulator pumps installed by GSHA Services in Woodstock, IL
A Navien condensing heating boiler serving three heating zones, installed by GSHA Services in Woodstock, IL.

Navien NHB-H and NFB-H heating boilers

These are wall-hung, heating-only condensing boilers for radiator, baseboard and radiant-floor systems, or for pairing with an indirect water heater. The NHB-H covers 55,000 to 150,000 BTU/h with dual stainless steel heat exchangers in a compact 17.3 x 23.8 x 12.8 in. cabinet. The NFB-H steps up to 175,000 and 199,900 BTU/h with Navien’s ASME-certified stainless fire tube heat exchanger and a longer heat-exchanger warranty. All six are 95% AFUE and ENERGY STAR certified, and Navien lists them for residential and commercial use; this page covers homes.

ModelHeating input rangeAFUETurndownHeat exchangerInstalled package price
NHB-55H8,000-55,000 BTU/h95%7:1Dual stainless steel$8,211.42
NHB-80H8,000-80,000 BTU/h95%10:1Dual stainless steel$8,408.80
NHB-110H10,000-110,000 BTU/h95%11:1Dual stainless steel$8,603.35
NHB-150H10,000-150,000 BTU/h95%15:1Dual stainless steel$8,950.00
NFB-175H13,300-175,000 BTU/h95%13.2:1Stainless steel fire tube, ASME H-stamp$9,512.23
NFB-200H13,300-199,900 BTU/h95%15:1Stainless steel fire tube, ASME H-stamp$9,236.00

A higher turndown means the boiler can idle at a small flame on a mild day instead of cycling on and off, which is quieter, easier on parts and keeps supply temperatures even. The NHB-H has built-in zoning for a boiler pump plus three zone pumps or three zone valves, so many homes need no external zone panel. Navien’s NFB-H series page lists NaviLink ($288.43) and NaviLink Lite ($153.55) Wi-Fi control as optional accessories; for the NHB-H models we confirm NaviLink compatibility at the estimate.

If you are comparing brands, see our Weil-McLain boilers and Peerless boilers pages, or the boiler installation hub.

Navien NPF hydro furnaces

For homes heated by ductwork rather than radiators, Navien’s NPF700 series is a condensing hydro furnace: its own 97% AFUE modulating gas burner heats water in a sealed internal loop, and a variable-speed ECM blower moves warm air across a coil into the ducts. Because the burner modulates from 15 to 100 percent of its rating, the furnace can run long, low cycles instead of blasting on and off, and it can pair with a matched air-conditioning coil or heat pump. GSHA installs three sizes as complete packages; because the price book has no separate NPF installation scope line, the free estimate confirms exactly what the installation includes for your ductwork, venting and condensate drain.

ModelHeating input (max)Airflow orientationAFUEInstalled package price
NPF700-060H3BH60,000 BTU/hHorizontal97%$5,993.38
NPF700-100H5CH100,000 BTU/hHorizontal97%$6,331.72
NPF700-100U5CH100,000 BTU/hUpflow97%$6,331.72

Specifications are from Navien’s NPF model pages. Navien’s residential NPF warranty depends on online registration within 60 days of installation; the model pages list the current terms, and we review them with you at the estimate.

Copper supply and return piping on a Navien NCB-240/110H combi-boiler installed by GSHA Services
Primary manifold, hydraulic separator and isolation valves on a GSHA combi-boiler installation in Woodstock, IL.

What Navien boiler installation costs and what’s included

Navien combi-boilers are installed from $10,342.85 (NCB-240/110H) to $11,136.53 (NFC-250/200H); heating boilers from $8,211.42 (NHB-55H) to $9,512.23 (NFB-175H). Each is a complete installed package: equipment, materials, labor, removal of the old unit and start-up. The combi-boiler and boiler packages include different materials because the systems are piped differently.

Standard combi-boiler installation (NCB-H and NFC-H) includes:

  • Setting and leveling the unit; water piping modifications
  • Gas line modification with a new gas valve; new condensate drain line
  • New 150 lb pressure relief valve; 4.8-gallon hydronic expansion tank and a domestic-water thermal expansion tank
  • Navien primary manifold kit; NaviClean magnetic filter; commissioning chemicals (Protector F1 and Cleaner F3)
  • New PVC flue venting
  • Removal and disposal of the old equipment; start-up, testing and safety inspection

Standard heating-boiler installation (NHB-H and NFB-H) includes:

  • Setting and leveling the boiler on a floor stand; new electrical disconnect with power and control wiring
  • Supply and return connections with 1-1/4 in. isolation flanges; new 3-speed cast-iron circulator; aquastat; autofill combination valve
  • 1-1/4 in. hydraulic separator; expansion tank; hydronic docking station
  • 3 in. PVC venting with sidewall vent kit; commissioning chemicals (F1/F3)
  • Honeywell T4 Pro hydronic thermostat
  • Removal of the old boiler; start-up and safety inspection; a boiler tune-up at the one-year mark

What can change the final quote: gas line capacity and length; venting route and length; where the condensate can drain; water quality treatment; electrical work; zoning and piping changes such as adding zone valves or an indirect tank; permits; accessories such as NaviLink or NaviCirc; and how accessible the installation location is. We confirm all of this during a free in-home estimate.

Financing is available with approved credit; see our financing page for details.

Request an Installation Estimate or call (224) 220-3660.

Navien warranty and GSHA Install-Right coverage

Two separate warranties apply to a GSHA-installed Navien boiler. Navien’s residential limited warranty covers the product; GSHA’s Install-Right coverage adds labor and parts protection on top of it. They are not the same thing, so we list them separately.

Navien residential limited warranty (single-family homes):

  • NCB-H and NFC-H combi-boilers: 1-year labor, 5-year parts, 10-year heat exchanger.
  • NHB-H boilers: 1-year labor, 5-year parts, heat exchanger fully covered for 10 years, then pro-rated in years 11 through 15 (the homeowner pays 30% to 70% of the heat exchanger cost).
  • NFB-H boilers: 1-year labor, 5-year parts, heat exchanger fully covered for 12 years, then pro-rated in years 13 through 15 (50% to 70%).

Navien’s warranty runs from the date of original installation, and that date (with proof on request) must be provided to Navien; GSHA gives you the installation paperwork you need. Navien also voids its warranty on units bought through the internet or from an unauthorized supplier and requires installation by a licensed contractor, which is one reason to buy the unit and the installation together.

GSHA Install-Right coverage (GSHA’s own add-on):

  • Combi-boiler packages (NCB-H, NFC-H): 5-year parts and 5-year labor coverage from GSHA. Labor coverage stays in force only with annual GSHA maintenance; service by anyone other than GSHA voids it. The heat exchanger itself is covered by Navien’s 10-year residential term.
  • Heating-boiler packages (NHB-H, NFB-H): 10-year parts and 10-year labor coverage from GSHA, beyond Navien’s 5-year parts and 1-year labor. The same condition applies: annual GSHA maintenance keeps the labor coverage active, and service by others voids it.

Annual maintenance is not just a warranty condition. A condensing boiler needs a yearly check to hold its efficiency, and Navien lists failure to perform regular maintenance among the things that void its own warranty.

Navien boiler FAQs

How much does a Navien combi-boiler cost installed?

Navien combi-boilers are installed from $10,342.85 for the NCB-240/110H up to $11,136.53 for the NFC-250/200H as complete GSHA packages. The price includes the unit, gas and water piping modifications, condensate drain, expansion tanks, primary manifold, magnetic filter, PVC venting, removal of the old equipment and start-up. Gas line, venting route and zoning changes can move the final number, which is why we confirm it with a free estimate.

What is the difference between the Navien NCB-H and NFC-H?

The NFC-H is the larger combi-boiler with a fire tube heat exchanger, and the NCB-H is the compact combi with dual stainless heat exchangers. NCB-H heating input runs 60,000 to 150,000 BTU/h; the NFC-H reaches 175,000 or 199,900 BTU/h with a 13:1 or 15:1 heating turndown. Both produce the same top hot-water rating at the largest sizes (210,000 BTU/h, 5.4 GPM at a 70°F rise), and both carry Navien’s 1 / 5 / 10-year residential warranty.

Which Navien boiler size do I need?

The right size comes from a heat-loss calculation of your home, not from the size of the old boiler. Navien’s heating inputs run from 55,000 BTU/h (NHB-55H) and 60,000 BTU/h (NCB-190/060H) up to 199,900 BTU/h (NFB-200H and NFC-250/200H). For a combi, we also match hot-water flow at a 70°F winter rise (4.1 GPM on the NCB-190 models, 5.1 GPM on the NCB-240 models, 5.4 GPM on the NCB-250/150H and NFC-H) to how many showers run at once.

Can a Navien combi-boiler replace my tank water heater and boiler?

Yes, that is exactly what the NCB-H and NFC-H are designed to do: one wall-hung unit provides both hydronic heating and on-demand domestic hot water. You reclaim the floor space of the old boiler and tank, and hot water no longer runs out. The combi must be sized for your peak hot-water demand; for a household with several bathrooms in use at once, a heating-only boiler with an indirect tank can be the better fit.

Does GSHA service Navien boilers it did not install?

Yes. GSHA Services is a Navien Service Specialist with Navien Level 3 trained technicians, and we repair and maintain Navien NCB, NCB-H, NFC, NFC-H, NHB, NHB-H, NFB and NFB-H boilers and NPE tankless water heaters regardless of who installed them. Navien’s product warranty stays with the unit; GSHA’s own labor coverage applies only to systems we installed and maintain.

What maintenance keeps the GSHA labor warranty in force?

An annual GSHA maintenance visit keeps the Install-Right labor coverage active on both combi-boiler and heating-boiler packages. A typical annual visit covers items such as the condensate trap, a combustion check, the heat exchanger, venting and safety controls; your maintenance agreement lists the exact scope. Service by another company voids GSHA’s labor coverage, though it does not affect Navien’s product warranty.

Get a Navien boiler installation estimate

Tell us how your home is heated today and how many bathrooms you have, and we will recommend the Navien model that fits and give you a written installed price. Estimates are free, and financing is available with approved credit.

Request an Installation Estimate or call (224) 220-3660. For tankless water heaters, see Navien tankless water heater prices or our water heater services.

Recent Navien boiler installations by GSHA Services

Navien Boiler Installation and Repair Service Areas

GSHA Services installs and services Navien combi-boilers and boilers across McHenry County and Lake County, Illinois, the northern and western Chicago suburbs and southeastern Wisconsin. We also service and repair existing Navien NPE tankless water heaters. Explore our service areas or contact us to confirm availability at your address.

  • McHenry County: Woodstock, Crystal Lake, McHenry, Cary, Algonquin, Lake in the Hills, Huntley, Harvard, Marengo
  • Lake County: Lake Bluff, Lake Forest, Libertyville, Mundelein, Vernon Hills, Lake Zurich, Wauconda, Grayslake, Gurnee, Waukegan, Antioch
  • Northwest suburbs: Barrington, Arlington Heights, Palatine, Schaumburg, Elgin
  • Southeastern Wisconsin: Kenosha, Racine, Lake Geneva, Burlington, Waukesha

About GSHA Services, LTD

GSHA Services, LTD is a family-owned heating, cooling and plumbing contractor serving northern Illinois and southeastern Wisconsin since 2002. We are a Navien Service Specialist (NSS), listed on Navien’s installer locator at navieninc.com, and our technicians are Navien Level 3 trained. We install Navien NPE-2 tankless water heaters and service existing NPE units, and we install and service NCB-H and NFC-H combi-boilers and NHB-H and NFB-H boilers.