Williams wall and floor furnaces. Local GSHA installation.
Authorized Williams Dealer and Installer in Northern Illinois
GSHA Services, LTD is an authorized dealer and installer of Williams Comfort Products heating equipment: direct-vent and high-efficiency direct-vent wall furnaces, Forsaire counterflow furnaces, Monterey top-vent gravity furnaces, floor furnaces, vented room (console) heaters and garage and workshop furnaces. Our own crews install and service them from offices in Woodstock and Lake Bluff for homeowners in McHenry, Lake, Boone, Kane, DuPage, Cook and Will counties.
A Williams furnace heats a room or a zone without ductwork, which makes it the practical answer for an addition, a garage or workshop, a cabin-style three-season room, a basement, a small apartment or an older house whose original wall or floor furnace has reached the end of its life. Every Williams installation from GSHA starts with a free in-home estimate: a heat-loss check for the space, a look at the wall or roof where the vent will go, the gas line and, where the model needs it, the electrical outlet or circuit. Request a free installation estimate or call (224) 220-3660.
Authorized Williams dealer and installerGSHA Services, LTD · Woodstock & Lake Bluff, IL
Why the installer matters with Williams
Williams warranties depend on a qualified installer
Williams Comfort Products traces its start to 1916, when Jesse Williams began building gas steam radiators in Los Angeles, and today the company says it performs its engineering, research and development, testing and manufacturing at its factory in Colton, California. Williams sells its furnaces through distributors and manufacturer’s representatives rather than direct to homeowners, and its literature is blunt about installation: the spec sheets state that the combustion chamber carries a 10-year limited warranty and all other parts a one-year limited warranty, that the warranty is contingent on installation by a qualified installer or contractor, and that self-installation is prohibited and will invalidate the warranty.
That is the role GSHA fills. GSHA is an authorized Williams dealer and installer: we size the unit, supply it, run the gas piping, install the vent kit exactly as the Williams manual describes, pull the permit, light and test the appliance, and walk you through the thermostat and pilot.
Our own crews, our own licensed electricians
The technicians who install your Williams furnace work for GSHA. Several Williams models need no electricity at all, but the Forsaire counterflow furnaces and the 17,700 BTU/hr high-efficiency direct-vent model run a blower on 115 or 120 volts, and optional blowers for gravity models and console heaters need power too. When an outlet or a hardwired circuit is required, GSHA’s own licensed electricians install it under the same job. GSHA also installs central furnaces, boilers, heat pumps and mini-splits from other manufacturers, so if a ducted or ductless system would serve the space better, the estimate says so.
Questions before you book?
Call (224) 220-3660 or email info@gshaservices.com. Reviews of GSHA are published on Google.
Useful links
Current Williams offers
Ask GSHA about current Williams offers.
Williams did not list a consumer promotion on its website when we checked on October 23, 2026, so we do not publish one here. Financing programs available through GSHA are on our financing page. See financing options.
Gas-utility furnace rebates in northern Illinois are tiered at 95 and 97 percent AFUE, and the Williams models on this page are rated at or below 80 percent AFUE, so they generally fall outside those furnace rebates. We confirm current utility programs with you during the estimate rather than promising a rebate up front.
Explore Williams products
Eight Williams furnace and heater lines GSHA can supply and install. Ratings, sizes and requirements below come from the current Williams product pages and spec sheets listed under Sources; final model choice is confirmed at the free estimate.
Direct-Vent Wall Furnaces
Compact gravity wall furnaces that draw combustion air from outdoors and vent through the wall behind them. Williams lists them as needing no electricity, so they keep heating in a power outage.
Sizes: 14,000, 22,000 and 30,000 BTU/hr
Models and specs
- 1403821 / 1403822 (natural / propane) — Input 14,000 BTU/hr · Output 9,800 BTU/hr · Millivolt
- 2203821 / 2203822 — Input 22,000 BTU/hr · Millivolt · No electricity required
- 3003821 / 3003822 — Input 30,000 BTU/hr · Output 21,000 BTU/hr · Millivolt
- Matchless pilot igniter · All vent materials included · 24-inch maximum wall thickness · Optional 115V high-capacity blower (Model 2302 or 2303)
Specs from the Williams Direct-Vent spec sheet. Williams publishes efficiency figures per model on the spec sheet; GSHA quotes the figure for the exact model on your estimate.
High-Efficiency Direct-Vent
Low-profile, wall-mounted sealed-combustion furnaces with a small concentric vent cap. Williams describes them as installable nearly anywhere, including homes, apartments, offices, garages and room additions.
Sizes: 7,400 and 17,700 BTU/hr
Models and specs
- 0743511 / 0743512 — Input 7,400 BTU/hr · Output 5,500 BTU/hr · Requires no electricity · Built-in programmable seven-day timer · Max wall 19 1/2 in.
- 1773511 / 1773512 — Input 17,700 BTU/hr · Output 13,500 BTU/hr · 120V · Two-speed recirculating fan for summer ventilation · Max wall 19 5/8 in.
- Sealed combustion chamber uses no indoor air · Wall-mount design needs no floor space · Natural and propane models
Specs from the Williams High-Efficiency Direct-Vent spec sheet.
Forsaire Counterflow
Tall, slim wall furnaces with a blower that moves warm air from ceiling to floor. Top-vent models vent up through the roof; direct-vent models vent through the wall. Optional outlet kits can heat up to three rooms.
Top-vent 35,000-65,000 BTU/hr · Direct-vent 40,000-60,000 BTU/hr
Models and specs
- Efficiency: up to 80% AFUE (e.g. 3508632, 5008632 and 4007732 are listed at 80% AFUE)
- Blower: one- or two-speed, 240 to 440 CFM, 115V with a 4-foot power cord
- Ignition: standing-pilot and intermittent-ignition versions, matchless pilot igniter
- Clearances: 4 in. to an intersecting wall, 0 in. to the finished floor; thermostat sold separately
Specs from the Williams Forsaire spec sheet (June 2026 edition).
Monterey Top-Vent Gravity
The traditional gravity wall furnace, recessed into the stud space or surface-mounted, venting up through the ceiling and roof. A dual-wall version heats two adjoining rooms. No electricity required.
Sizes: 25,000, 35,000 and 50,000 BTU/hr (dual-wall 25,000 each side)
Models and specs
- 2509621A / 2509622A — Input 25,000 BTU/hr · Output 17,870 BTU/hr
- 3509621A / 3509622A — Input 35,000 BTU/hr · Output 23,700 BTU/hr
- 5009622A (dual-wall) — Input 50,000 BTU/hr · Output 36,900 BTU/hr
- Millivolt with matchless pilot igniter · Oval-vent starter kit · Optional blowers and rear-outlet registers
Specs from the Williams Monterey spec sheet (June 2026 edition).
Floor Furnaces
A furnace hung below the floor that circulates warm air up through a floor register without a blower. The combustion chamber lifts out for service. Common as a replacement in older homes that already have one.
Sizes: 45,000 and 60,000 BTU/hr
Models and specs
- 4505621A / 4505622A — Input 45,000 BTU/hr · Output 31,000 BTU/hr
- 6005621A / 6005622A — Input 60,000 BTU/hr · Output 42,000 BTU/hr
- Thermal efficiency 70%, AFUE 58.0 · Millivolt · No electricity required · 4-inch vent pipe rising 1/4 inch per foot
- Needs an 18-inch working space at the control end and 12 inches on other sides below the floor
Specs from the Williams Floor Furnace spec sheet.
Vented Room (Console) Heaters
Free-standing vented console heaters in enclosed and glass-front, fireplace-look styles with ceramic fiber logs. The heater itself needs no electricity; an optional blower adds circulation.
Sizes: 20,000, 35,000, 50,000 and 65,000 BTU/hr
Models and specs
- 200 series (enclosed, compact) — Input 20,000 BTU/hr · Output 15,500 BTU/hr · 3-inch vent
- 350 series — Input 35,000 BTU/hr · Output 25,000 BTU/hr · 4-inch vent
- 500 series — Input 50,000 BTU/hr · Output 34,500 BTU/hr · 4-inch vent
- 650 series — Input 65,000 BTU/hr · Output 47,000 BTU/hr · 5-inch vent
- Optional Model 2102 blower, 120V, 150 CFM · Resettable vent-limit safety switch · Millivolt thermostat sold separately
Specs from the Williams Vented Room Heaters spec sheet (June 2026 edition).
Garage and Workshop Furnaces
Williams markets three direct-vent lines for garages and workshops: Direct-Vent Counterflow (blower, 4-foot power cord), Direct-Vent Gravity (no electricity) and Direct-Vent High-Efficiency (no inside air used for combustion).
Natural or propane · Conversion kits available
Models and specs
- Counterflow: 40,000-60,000 BTU/hr input, 77-80% AFUE per the Williams garage spec sheet, 12-inch maximum wall thickness
- Gravity: 14,000-30,000 BTU/hr input, 24-inch maximum wall thickness, works during power outages
- High-efficiency: 7,400 and 17,700 BTU/hr input
- All vent materials included · Vent cap guard and vent shield accessories available
Specs from the Williams Garage Furnaces spec sheet.
Solana Electric Counterflow
For spaces without gas service, Williams makes the Solana electric counterflow furnace: thermostat-controlled (thermostat sold separately), freestanding or recessed, with a flat white finish.
Electric · Freestanding or recessed
Notes
- Williams does not list kW or voltage on the Solana product page; GSHA confirms the electrical requirement from Williams literature before quoting and sizes the circuit with our own licensed electricians.
Choose a Williams heater
Williams equipment is zone heating: each unit heats the room it is in, or a few adjoining rooms with an outlet kit, rather than the whole house through ducts. Which line fits depends on how you can vent it, whether there is power where it will go, and how much heat the space loses.
Through an outside wall: direct-vent
If the furnace can sit on an exterior wall, a direct-vent model is usually the cleanest installation. Williams describes the design this way: combustion air comes from outside through the vent, the burners are sealed in the combustion chamber, and the products of combustion leave through the same wall, so no room air is used for combustion. The gravity direct-vent models (14,000 to 30,000 BTU/hr) handle walls up to 24 inches thick and need no electricity; the Forsaire direct-vent counterflow models (40,000 to 60,000 BTU/hr) add a blower and handle walls up to 12 inches; and the high-efficiency direct-vent models (7,400 and 17,700 BTU/hr) mount on the wall with no floor space and use a small concentric vent cap. All vent materials come with the furnace.
Up through the roof: top-vent
Where the furnace belongs on an interior wall, or an old wall furnace already has a vent through the roof, a Monterey top-vent gravity furnace or a Forsaire top-vent counterflow furnace vents vertically through the ceiling and roof using Williams’ oval vent system. Monterey units recess into the stud space or surface-mount, and the dual-wall Monterey heats the rooms on both sides of the wall at 25,000 BTU/hr each. GSHA inspects any existing vent before reusing it and replaces it if it is not suitable.
Below the floor: floor furnace
Floor furnaces suit homes built over a crawl space or basement where a floor furnace is already installed, or where wall space is scarce. Williams’ 45,000 and 60,000 BTU/hr models move air by natural convection with no blower and no electricity. Williams lists them at 58.0 AFUE, lower than its wall furnaces, so we discuss a wall or counterflow alternative whenever one would fit.
A visible heat source: console room heaters
Vented room heaters sit on the floor against a wall and vent through a 3- to 5-inch vent depending on size. The 350, 500 and 650 series have a glass front with ceramic fiber logs for a fireplace look; the compact 200 series is enclosed. They suit a family room, a cabin-style space or a room where a free-standing heater is preferred to a wall unit.
No gas: Solana electric
Where there is no gas service at all, the Solana electric counterflow furnace keeps the same slim, floor-to-ceiling format. A ductless mini-split heat pump is the other option we price for an all-electric space.
Sizing and venting are confirmed for your space during the free estimate. Williams publishes a BTU calculator as a starting point; GSHA measures the room, checks insulation, windows and ceiling height, looks at the wall or roof where the vent will go, confirms the gas line and the electrical supply, and quotes the specific model in writing.
Why the installation matters
A wall or floor furnace is a sealed gas appliance with a vent that passes through your house. These are the steps GSHA performs on every Williams installation.
- Sizing. We size the unit from the space it must heat, not from the old unit’s label. Williams lists input and output ratings for every model; output is the heat delivered to the room, and that is the number we match to the heat loss.
- Location and clearances. Williams spec sheets set the clearances we design to, such as 4 inches from an intersecting wall and 0 inches to the finished floor for Forsaire counterflow furnaces, 2 inches from an intersecting wall for direct-vent gravity models, and 6 inches from an adjacent wall and 12 inches from doors and drapes for floor furnaces. Furniture and drapes stay clear of the heater front.
- Venting. Direct-vent units use the vent kit supplied by Williams, within the maximum wall thickness for the model, with thin-wall collars, vent extensions or a vent cap guard where the wall or walkway calls for them. Top-vent units use the Williams oval vent system through the roof. The vent termination follows the Williams installation manual and the local fuel gas code.
- Gas piping and fuel. Williams furnaces have a 1/2-inch gas connection and come in natural-gas and propane versions, with conversion kits listed for each size. GSHA runs and tests the gas line, installs the shut-off and sets the unit up for your fuel.
- Power where needed. Gravity, Monterey, floor and console units need no electricity. Counterflow units ship with a 4-foot power cord (a hardwire adapter is available), and the 17,700 BTU/hr high-efficiency unit and optional blowers need a 115 to 120 volt supply. GSHA’s licensed electricians add the outlet or circuit.
- Permits and inspection. Installing a gas heating appliance is permitted mechanical work in the municipalities we serve; GSHA pulls the permit and schedules the inspection. County pages below summarize the local rules.
- Start-up and handoff. We light the pilot with the matchless igniter, check the burner, vent and thermostat operation, and show you how to relight the pilot and use the thermostat. Your invoice records the model and serial numbers you will need for any Williams warranty claim.
Find your county
GSHA installs and services Williams equipment from two offices: Woodstock (McHenry County) and Lake Bluff (Lake County). Crews travel from those offices into Boone, Kane, DuPage, Cook and Will counties. Each county page covers the communities we serve, how local permits and gas utilities affect a wall or floor furnace installation, and how to get an estimate. The ZIP-code list is the definitive coverage map.
Questions and answers
Is GSHA an authorized Williams dealer?
Yes. GSHA Services, LTD is an authorized Williams dealer and installer. Williams sells its furnaces through distributors and manufacturer’s representatives and states that its warranties are contingent on installation by a qualified installer or contractor; GSHA supplies the equipment and performs the installation, so the warranty conditions are met.
Do Williams wall furnaces need electricity?
It depends on the line. Williams lists the direct-vent gravity furnaces, the 7,400 BTU/hr high-efficiency direct-vent model, the Monterey top-vent furnaces, the floor furnaces and the vented room heaters as needing no electricity, which means they keep heating during a power outage. The Forsaire counterflow furnaces have a 115V blower with a 4-foot cord, the 17,700 BTU/hr high-efficiency model runs on 120V, and optional blowers need power. GSHA also installs standby generators if you want the rest of the house covered in an outage.
Natural gas or propane?
Both. Williams makes natural-gas and propane versions and lists conversion kits by size, for example kit 8939 to convert the 14,000 BTU/hr direct-vent furnace from natural gas to propane. Tell us your fuel when you request the estimate.
Can a Williams furnace heat my garage or workshop?
Yes. Williams markets direct-vent counterflow, gravity and high-efficiency direct-vent models for garages and workshops, and describes the high-efficiency and Forsaire direct-vent models as ideal for garages. Codes add requirements for fuel-burning appliances in garages, so GSHA confirms placement with your municipality. See also our garage heater installation page, which covers unit heaters from other manufacturers.
Will a Williams furnace qualify for a gas-utility rebate?
Usually not. Nicor Gas, Peoples Gas and North Shore Gas tier their 2026 residential furnace rebates at 95 and 97 percent AFUE, and the Williams furnaces on this page are rated at or below 80 percent AFUE. A Williams unit is chosen for zone heating without ductwork, not for a rebate; if a high-efficiency central furnace makes more sense for your house, we will say so at the estimate.
What size do I need?
Williams sizes range from 7,400 BTU/hr (high-efficiency direct-vent) to 65,000 BTU/hr (Forsaire top-vent and the 650 series room heater). The right size depends on the room’s floor area, ceiling height, insulation, windows and how cold the space runs. Williams offers an online BTU calculator; GSHA confirms the size on site.
What warranty comes with a Williams furnace?
The current Williams spec sheets state a 10-year limited warranty on the combustion chamber and a one-year limited warranty on all other parts, contingent on installation by a qualified installer. They also state that self-installation is prohibited and will invalidate the warranty.
Can you replace an old wall or floor furnace from another brand?
Yes. Replacing a worn-out wall or floor furnace is one of the most common reasons homeowners ask about Williams. We check whether the existing opening, vent and gas line can be reused, confirm the new unit’s clearances, and quote any changes up front.
Do you service Williams furnaces you did not install?
Yes. GSHA repairs and maintains Williams wall furnaces, floor furnaces and console heaters regardless of who installed them, and we service other brands too. Call (224) 220-3660 or see our furnace repair page.
Are there any Williams offers right now?
Ask GSHA about current Williams offers. Williams did not list a consumer promotion on its site when this page was published, and financing through GSHA is described on our financing page.
Request a free Williams installation estimate
Tell us about the space you want to heat and the equipment you have now. We will follow up to schedule a free, no-obligation visit, measure the space, check the wall or roof for venting, the gas line and any electrical needs, and give you a written quote.
Send the form or call
Use the form here, book online, or call (224) 220-3660.
On-site visit
A GSHA comfort advisor measures the space, checks venting, gas and power, and explains the Williams options that fit.
Written quote
You receive an itemized quote with the equipment, vent kit, gas piping, any electrical work and the permit. No obligation.
If the form does not load, email info@gshaservices.com or call (224) 220-3660.
About GSHA Services, LTD
GSHA Services, LTD is a licensed and insured heating, cooling, electrical, plumbing and generator contractor and an authorized Williams dealer and installer. Offices: 1257 Cobblestone Way, Suite A, Woodstock, IL 60098 and Lake Bluff, IL. Phone (224) 220-3660. Email info@gshaservices.com. We install and service Williams wall furnaces, floor furnaces and room heaters across the northern and western Chicago suburbs; see the full service area by ZIP code. Contact us · Financing · Maintenance plans · All products and brands
Sources
- Williams Comfort Products, About (history since 1916; Colton, CA engineering and manufacturing) — https://williamscomfort.com/about/ (accessed 2026-10-23)
- Williams Comfort Products home page (product lines; where to buy; warranties contingent on qualified installer) — https://williamscomfort.com/ (accessed 2026-10-23)
- Williams Direct Vent Furnaces product page — https://williamscomfort.com/product/direct-vent-furnaces/ (accessed 2026-10-23)
- Williams Direct-Vent spec sheet L1109 (June 2026) — https://williamscomfort.com/wp-content/uploads/2026/06/L1109_Direct_Vent_specSheet_6_26.pdf (accessed 2026-10-23)
- Williams Direct-Vent Gravity installation and owner’s manual P322101 — https://williamscomfort.com/wp-content/uploads/2026/06/P322101_G_Direct_Vent_Gravity_EN.pdf (accessed 2026-10-23)
- Williams High Efficiency Direct Vent Furnaces product page — https://williamscomfort.com/product/high-efficiency-direct-vent-furnaces/ (accessed 2026-10-23)
- Williams High-Efficiency Direct-Vent spec sheet L1457 — https://williamscomfort.com/wp-content/uploads/2023/09/L1457_High_Efficiency-DV_spec_sheet-8_25.pdf (accessed 2026-10-23)
- Williams Forsaire Direct Vent Counterflow Furnaces product page — https://williamscomfort.com/product/forsaire-direct-vent-counterflow-furnaces/ (accessed 2026-10-23)
- Williams Forsaire Top Vent Counterflow Furnaces product page — https://williamscomfort.com/product/forsaire-top-vent-counterflow-furnaces/ (accessed 2026-10-23)
- Williams Forsaire spec sheet L1158 (June 2026) — https://williamscomfort.com/wp-content/uploads/2026/06/L1158_Forsaire_spec_sheet_EN_6_26.pdf (accessed 2026-10-23)
- Williams Monterey Top Vent Gravity Furnace product page — https://williamscomfort.com/product/monterey-top-vent-gravity-furnace/ (accessed 2026-10-23)
- Williams Monterey spec sheet L1073 (June 2026) — https://williamscomfort.com/wp-content/uploads/2026/06/L1073_Monterey_spec_sheet_6_26_EN.pdf (accessed 2026-10-23)
- Williams Floor Furnaces product page — https://williamscomfort.com/product/floor-furnaces/ (accessed 2026-10-23)
- Williams Floor Furnace spec sheet L1026 — https://williamscomfort.com/wp-content/uploads/2023/09/L1026_Floor_Furnaces_specSheet_4-21.pdf (accessed 2026-10-23)
- Williams Vented Room Heaters product page — https://williamscomfort.com/product/vented-room-heaters/ (accessed 2026-10-23)
- Williams Vented Room Heaters spec sheet L1013 (June 2026) — https://williamscomfort.com/wp-content/uploads/2026/06/L1013_Vented_Room_Heaters_specSheets_6_9_2026.pdf (accessed 2026-10-23)
- Williams Garage and Workshop Heaters page — https://williamscomfort.com/products/furnaces/williams/garage-workshop-heaters/ (accessed 2026-10-23)
- Williams Garage Furnaces spec sheet L1171 — https://williamscomfort.com/wp-content/uploads/2023/09/L1171_Garage_spec_sheet_4_21-1.pdf (accessed 2026-10-23)
- Williams Solana Electric Counterflow Furnace product page — https://williamscomfort.com/product/solana-electric-counterflow-furnace/ (accessed 2026-10-23)
- Williams Literature and Videos — https://williamscomfort.com/literature-and-videos/ (accessed 2026-10-23)
- Williams BTU Calculator — https://williamscomfort.com/btu-calculator/ (accessed 2026-10-23)
- Nicor Gas Residential Energy Efficiency Rebates 2026 — https://www.nicorgas.com/ways-to-save/residential-savings/rebates.html (accessed 2026-10-23)
- Peoples Gas residential rebates — https://www.peoplesgasdelivery.com/savings/rebates-residential (accessed 2026-10-23)
- North Shore Gas residential rebates — https://www.northshoregasdelivery.com/savings/rebates-residential (accessed 2026-10-23)
- GSHA Garage Heater Installation — https://gshaservices.com/hvac-services-illinois-wisconsin/garage-heater-installation/ (accessed 2026-10-23)
- GSHA service area page (ZIP-code list) — https://gshaservices.com/about-gsha-services/service-area/ (accessed 2026-10-23)
- GSHA financing page — https://gshaservices.com/financing/ (accessed 2026-10-23)