GSHA Services, LTD is an authorized Generac dealer and installer with offices in Woodstock and Lake Bluff. Our own crews and our own licensed electricians install, service and maintain Generac home standby generators, automatic transfer switches, load management controls and Mobile Link monitoring for homeowners in McHenry, Lake, Boone, Kane, DuPage, Cook and Will counties.
Every Generac installation from GSHA starts with a free in-home estimate: a look at your electrical panel and service, a gas load check on your meter and piping, a walk around the lot to find a code-compliant spot for the generator, and a written quote for the size and transfer switch your house actually needs rather than the biggest unit on the truck. Request a free installation estimate or call (224) 220-3660.

Authorized Generac dealerGSHA Services, LTD · Woodstock & Lake Bluff, IL
An authorized Generac dealer with its own crews
One company from the estimate to the start-up
A home standby generator touches three trades at once: electrical work at the panel and transfer switch, fuel-gas piping from the meter or propane tank, and site work for the pad. Many installations split those among subcontractors. At GSHA the estimator, the electricians, the gas-line technicians and the crew that sets the generator all work for GSHA, so the person who sized the system is talking to the people who install it, and one company answers for the result. Generac itself states in its owner’s manual that only qualified service personnel may install its generators, that wiring and connections should be performed only by a trained and licensed electrician, and that the fuel connection must be completed by a qualified professional; that is exactly the split of work GSHA keeps in-house.
Licensed electricians in-house
The transfer switch is the part of a standby system that decides whether your house is safe during an outage. It separates the home from the utility line before the generator powers anything, so no current flows back toward utility crews, and it returns the house to utility power when service is restored. GSHA’s own licensed electricians install the switch, move your circuits, run the conduit and control wiring to the generator, and meet the electrical inspector. If your panel or service needs an upgrade to accept a service-entrance-rated switch, the same team does that work under the same permit.
We install more than one brand
GSHA also installs and services KOHLER and other brands of home generators, and our technicians work on generators we did not install. That means the recommendation you get is based on your house, your fuel and your lot, not on a single catalog. When Generac is the right fit, this page explains how we choose the size, the switch and the options.
Current Generac offers
Ask GSHA about current Generac offers.
Generac runs promotions at different times of year, and each one names its own qualifying models, purchase window and claim rules. Rather than print an offer that may have ended, we confirm what applies to your generator and installation date when we write your quote. Financing through Synchrony and Service Finance is available to qualified buyers, subject to credit approval. See financing options.
Offer details and eligibility are set by Generac and the lender, not by GSHA, and can change without notice.
Explore Generac products
Eight things we install, set up or service on a Generac standby system. Specifications are Generac’s published figures from its current spec sheets and product pages; the output a generator delivers on your property depends on the fuel, the gas supply and the installation.

Generators, 10 to 18 kW
The smaller sizes in Generac’s current air-cooled line, for essential circuits or a smaller whole house. All three run on natural gas or propane and share the Power Zone 200 controller.
Featured: 10 kW (7257), 14 kW (7258), 18 kW (7259)
Featured models and ratings
- 10 kW: 10 kW on propane / 9 kW on natural gas; G-Force 400 Series engine; 61 dB(A) at normal load, 49 dB(A) in Quiet-Test low-speed exercise (at 23 ft)
- 14 kW: 14 kW on propane or natural gas; G-Force 800 Series engine; 65 dB(A) normal, 55 dB(A) Quiet-Test
- 18 kW: 18 kW on propane / 17 kW on natural gas; G-Force 800 Series engine; 65 dB(A) normal, 55 dB(A) Quiet-Test
Generac spec sheet figures. Final sizing and pricing follow a free on-site estimate.

Generators, 22 to 28 kW
The larger air-cooled sizes, for whole-house backup on bigger homes, homes with two air conditioners or homes with electric ranges and well pumps. Generac calls the 28 kW the most powerful air-cooled standby generator.
Featured: 22 kW (7260), 24 kW (7261), 26 kW (7327), 28 kW (7282)
Featured models and ratings
- 22 kW: 22 kW propane / 21 kW natural gas
- 24 kW: 24 kW propane / 22.5 kW natural gas
- 26 kW: 26 kW propane / 24 kW natural gas
- 28 kW: 28 kW propane / 25 kW natural gas
- All four: G-Force 1000 Series 997cc engine, 67 dB(A) at normal load and 55 dB(A) in Quiet-Test exercise at 23 ft
Generac spec sheet figures. Final sizing and pricing follow a free on-site estimate.
Automatic Transfer Switches
Generac sells each generator alone or packaged with a Generac transfer switch: a 100 A limited-circuit switch with the 10 kW package, and a 200 A service-entrance-rated switch in a NEMA 3R enclosure with the 14 through 28 kW packages.
Packages: 7321 (10 kW), 7323, 7324, 7325, 7326, 7328, 7329
How we choose the switch
- Limited-circuit switch when only selected essential circuits will be backed up
- Service-entrance-rated switch for whole-house backup on a 200 A service
- Other amperages when the existing service calls for it, confirmed at the estimate
Load Management
Load management lets a generator carry a large load, such as a second air conditioner or an electric range, by switching it off briefly when the generator nears capacity. Generac lists its Load Manager, HVAC Energy Manager and the ecobee by Generac smart thermostat as options.
Featured: Load Manager 50 A (G007000-1), 100 A (G007006-1), HVAC Energy Manager (G007025-0), ecobee by Generac
When load management is neededMobile Link Monitoring
Generac’s current air-cooled generators have cellular Mobile Link connectivity standard. The free Basic plan shows status and history; paid Premium plans add immediate alerts and remote controls. We enroll the generator at start-up.
Plans: Basic (free), Single Generator Premium, Single Home Premium, Multi Home Premium
Mobile Link alerts explainedCold-Weather Accessories
Generac recommends a battery heater and an oil heater where temperatures fall below 32°F, and a breather heater below 0°F where heavy icing occurs. In northern Illinois we recommend the battery and oil heaters on every installation.
Featured: battery heater G007211-0, oil heater G007102-1, breather heater G007103-2
Why they matter hereMaintenance & Service
Oil and filter changes, air filter and spark plugs, battery testing and a load test, on the schedule in your generator’s owner’s manual. GSHA services Generac generators whether or not we installed them.
Service Schedule A / B reminders, battery checks, repairs
Generator tune-up and maintenanceAlarms & Error Codes
Red, yellow and green lights, numbered alarms and Mobile Link messages all mean something specific. Our plain-language guides explain what each one means and when to call.
Overcrank 1100, low oil pressure 1300, overload 2100, battery 2760 and more
Generac error codes explainedChoose a size
Generac’s current air-cooled home standby line comes in seven single-phase sizes from 10 to 28 kW. The right one depends on three things: what you want running during an outage, which fuel the generator will burn, and how much gas your meter and piping can deliver. The table shows Generac’s published figures for each size.
| Size | Generac model (alone / with switch) | Max output, propane / natural gas | Max current at 240 V, LP / NG | Natural gas use at full load | Sound at 23 ft, normal / Quiet-Test |
|---|---|---|---|---|---|
| 10 kW | 7257 / 7321 (100 A) | 10 / 9 kW | 42 / 38 A | 132 cu ft/hr | 61 / 49 dB(A) |
| 14 kW | 7258 / 7323 (200 A) | 14 / 14 kW | 58 / 58 A | 243 cu ft/hr | 65 / 55 dB(A) |
| 18 kW | 7259 / 7324 (200 A) | 18 / 17 kW | 75 / 71 A | 235 cu ft/hr | 65 / 55 dB(A) |
| 22 kW | 7260 / 7325 (200 A) | 22 / 21 kW | 92 / 88 A | 311 cu ft/hr | 67 / 55 dB(A) |
| 24 kW | 7261 / 7326 (200 A) | 24 / 22.5 kW | 100 / 94 A | 291 cu ft/hr | 67 / 55 dB(A) |
| 26 kW | 7327 / 7328 (200 A) | 26 / 24 kW | 108 / 100 A | 316 cu ft/hr | 67 / 55 dB(A) |
| 28 kW | 7282 / 7329 (200 A + ecobee) | 28 / 25 kW | 116 / 104 A | 297 cu ft/hr | 67 / 55 dB(A) |
Source: Generac air-cooled standby generator spec sheets (10/14/18 kW and 22-28 kW). Switch amperages are for Generac’s packaged models. Every size uses the same 46.4 x 26.3 x 30.7 inch enclosure; weight runs from 344 lb (10 kW) to 524 lb (28 kW).
Essentials or whole house
An essentials system backs up a chosen list of circuits: typically the furnace, refrigerator and freezer, sump pump, well pump if you have one, some lights and outlets, and the garage door. That is the job the 10 kW and its 100 A limited-circuit switch are packaged for. A whole-house system puts the entire panel on the generator through a service-entrance-rated switch, which in most homes with central air means 18 kW or more, and in larger homes with two air conditioners, an electric range or an electric dryer, 22 to 28 kW, often with load management. The deciding numbers are the running and starting loads of your biggest motors, mainly air-conditioner compressors and well pumps, which we measure or read from the nameplates at the estimate.
Natural gas or propane
Every current Generac air-cooled size runs on either fuel. Note in the table that most sizes are rated slightly higher on propane than on natural gas; the 14 kW is the exception, rated the same on both. Most homes in our seven counties heat with utility gas, according to the Census Bureau’s 2020-2024 American Community Survey, between about 78 percent in Boone County and about 88 percent in Will County, so natural gas is the usual fuel. On a rural lot without a gas main, the generator runs from a propane tank, and the tank size, regulator and the length of the line to the generator become part of the quote. Propane also matters for Boone County, where about 7 percent of occupied homes already heat with bottled, tank or LP gas.
Gas supply is part of sizing
A standby generator is a large gas appliance. At full load the 22 kW uses 311 cubic feet of natural gas per hour and the 26 kW 316, on top of your furnace, water heater, range and dryer. Generac lists the required supply pressure for the 28 kW as 3.5 inches of water column on natural gas and 10 inches on propane. If the existing meter, regulator or house piping cannot deliver that, the generator will struggle to carry its rated load, so our gas-line technicians check the meter and run before quoting, and when the utility needs to upgrade the meter we coordinate it with Nicor Gas, North Shore Gas or Peoples Gas as applicable.
Sizing is settled at the free estimate. GSHA lists the circuits you want backed up, reads the panel and service, checks the gas meter and piping, and quotes the generator, the transfer switch and any load management in writing. If you are between two sizes, we explain what the smaller one would and would not carry.
Why the installation matters
Two homes can get the same Generac model and end up with very different results. One starts every time and carries the whole house; the other trips on overload when the air conditioner kicks on, or sits on a pad that floods. The difference is the installation. These are the steps GSHA performs on a Generac installation.
- Load calculation and switch selection. We list what must run, measure or read the starting and running loads of the big motors, and pick the generator and switch together. A whole-house switch on an undersized generator invites overload alarms; a limited-circuit switch on a large generator wastes capacity.
- Placement. Generac allows installation as close as 18 inches to a structure, provided the unit is away from doors, windows and fresh air intakes and the location meets local codes. Local zoning can be stricter: some municipalities bar generators from front or corner side yards, require screening or set lot-line setbacks, so we check the plat of survey against the local rule before choosing the spot. We also keep the unit out of low spots that collect water and away from septic fields and wells.
- Pad. Our basic installation uses a durable gravel pad; a pre-cast concrete base is available as an option, as described on our Generac generators page.
- Gas piping. GSHA’s gas-line technicians size and run the line from the meter or tank, install the sediment trap and shutoff, and pressure-test the piping before the generator is started.
- Electrical. Our licensed electricians mount the transfer switch, move the circuits, run conduit and control wiring to the generator and install any load management modules.
- Cold-weather readiness. Generac recommends a battery heater and oil heater below 32°F and a breather heater below 0°F where heavy icing occurs. Northern Illinois winters meet the first condition every year, so we recommend at least the battery and oil heaters on every job and quote them up front.
- Permits and inspections. GSHA prepares the application, including the plat or site plan and equipment cut sheets when the authority asks for them, pulls the permit from your village, city or county, and meets the inspectors.
- Start-up and load test. We start the generator, simulate an outage so the switch transfers the house, run it under load, and confirm it returns to utility power and shuts down on its own.
- Handoff and registration. We show you the controller, the exercise schedule and how to read the status lights, enroll the generator in Mobile Link with you, and register it with Generac. Generac’s current spec sheets list a 5-year limited warranty covering the generator and transfer switch, and its owner’s manual says extended coverage can be purchased within 12 months of purchase and applies to registered units.
Living with a Generac: monitoring, exercise and maintenance
Mobile Link
Generac’s spec sheets say cellular Mobile Link connectivity is standard on its current air-cooled generators and lets you monitor the generator from a smartphone, tablet or PC. Generac’s support site describes a free Basic plan that shows generator status and status history, product manuals and a monthly email summary, but without immediate notifications. Paid Premium plans add immediate email, text and push notifications, the ability to run an exercise or change the exercise schedule remotely on compatible controllers, remote dismissal of maintenance reminders on supported controllers, fuel-monitor support on some plans and ecobee thermostat integration. Generac also notes that for its Next Generation Series generators (2025 to present), status monitoring is available through the mobile app rather than the website. We set up the account with you at start-up so you can decide which plan you want. If an alert arrives that you do not recognize, our Mobile Link alerts guide explains the common ones.
The exercise cycle and Quiet-Test
A standby generator runs a short self-test on a schedule so it is ready when the power fails. Generac’s current units use a Quiet-Test low-speed exercise mode, which the spec sheets rate at 49 dB(A) for the 10 kW and 55 dB(A) for the 14 through 28 kW at 23 feet, compared with 61 to 67 dB(A) when running under normal load. Your house does not transfer to the generator during an exercise unless utility power is actually lost. We set the exercise day and time with you at handoff, usually a weekday daytime slot so it does not bother neighbors.
Maintenance
Generac controllers display maintenance reminders labeled Service Schedule A and Service Schedule B. In Generac’s 2023 owner’s manual for its 10 to 26 kW air-cooled generators, Schedule A covers oil, oil filter and a battery check, and Schedule B adds the air cleaner, spark plugs and valve clearance; the manual also calls for an oil and filter change after the first 25 hours of operation and more frequent oil changes in sustained cold or hot weather. The exact intervals for your generator are in its own owner’s manual, which we follow. GSHA offers generator tune-ups and repairs, and our guide to Service Schedule A and B reminders explains what each one means.
When something goes wrong
Most service calls start with a light on the controller or an alarm in the app. Common ones include a battery problem, an overload when too much starts at once, or a generator that will not start during an outage. Our guide to the red, yellow and green lights and the full Generac error code library explain what each means and what is safe for a homeowner to check. Anything involving fuel, wiring or the engine is a job for a technician; call (224) 220-3660.
Find your county
GSHA installs and services Generac generators from two offices: Woodstock (McHenry County) and Lake Bluff (Lake County). Crews travel from those offices into Boone, Kane, DuPage, Cook and Will counties. Each county page covers the communities we serve there, who issues generator permits, which gas and electric utilities you will deal with, and local factors such as wells, sump pumps and flood risk that change the sizing. The ZIP-code list is the definitive coverage map; if you are on the edge of it, call and we will confirm your address.
Questions and answers
Is GSHA an authorized Generac dealer?
Yes. GSHA Services, LTD is an authorized Generac dealer and installer. We sell, install and service Generac home standby generators with our own crews and our own licensed electricians from offices in Woodstock and Lake Bluff.
What size Generac generator do I need?
It depends on what you want running, not on square footage alone. Essentials-only systems for the furnace, refrigerator, sump pump and lights are what the 10 kW package is built for; whole-house coverage with one central air conditioner usually starts around 18 kW; larger homes with two air conditioners, an electric range or a well pump often need 22 to 28 kW, sometimes with load management. We measure your actual loads at the free estimate and recommend the smallest size that does the job.
Can a Generac run on propane?
Yes. Every current Generac air-cooled home standby size runs on natural gas or propane, and most are rated a little higher on propane: the 22 kW, for example, is rated 22 kW on propane and 21 kW on natural gas. On a propane system we check the tank size and the line to the generator as part of the estimate.
How close to the house can the generator go?
Generac’s spec sheets allow installation as close as 18 inches to a structure, away from doors, windows and fresh air intakes and in accordance with local codes. Your municipality may add its own rules on which yard the unit may sit in, screening and lot-line setbacks, so we check the local code before choosing the spot.
How loud is a Generac generator?
Generac rates its current air-cooled units at 61 to 67 dB(A) at 23 feet under normal load and 49 to 55 dB(A) during the Quiet-Test low-speed exercise, depending on size. Placement on the lot and the distance to a neighbor’s windows make a real difference, and some villages publish noise limits that we check during permitting.
Do I need a permit?
In the communities we serve, a standby generator involves electrical and fuel-gas work that requires a permit from your village, city or county. GSHA prepares the application, pulls the permit and meets the inspectors; the fee your municipality charges is quoted separately. The county pages above explain who issues permits in each county.
Is Mobile Link free?
Generac offers a free Basic Mobile Link plan with generator status, history and a monthly email summary, and paid Premium plans that add immediate notifications and remote controls. Cellular connectivity is standard on Generac’s current air-cooled generators, so the generator can be enrolled without your home Wi-Fi.
Is financing available?
Yes. GSHA offers financing through Synchrony and Service Finance for qualified buyers, subject to credit approval. Current programs are on our financing page; ask your estimator which applies to your project.
Are there any Generac offers right now?
Ask GSHA about current Generac offers. Generac promotions carry specific model lists, dates and claim rules, so we confirm what applies to your generator and installation date when we write the quote rather than publishing offer details here.
Do you service Generac generators you did not install?
Yes. GSHA maintains and repairs Generac home standby generators regardless of who installed them, and we service other brands too. Call (224) 220-3660 to schedule.
More Generac pages
Generac air-cooled generator sizes and basic installation · Generac standby generator installation in Woodstock · Generac error codes and alarms · What the red, yellow and green lights mean · Mobile Link alerts · Testing in manual mode after an alarm · Home generator error codes, all brands · Generator installation
Request a free Generac installation estimate
Tell us about your home and what you want running during an outage. We will follow up to schedule a free, no-obligation in-home visit, check your panel, gas meter and piping, choose a spot for the generator, and give you a written quote.
Send the form or call
Use the form here, book online, or call (224) 220-3660.
In-home visit
A GSHA estimator reviews your loads, panel and gas supply and explains the Generac options that fit.
Written quote
You receive an itemized quote with the generator, transfer switch, permits, warranty registration and the work included. No obligation.
If the form does not load, email info@gshaservices.com or call (224) 220-3660.
About GSHA Services, LTD
GSHA Services, LTD is a licensed and insured heating, cooling, electrical, plumbing and generator contractor and an authorized Generac dealer. Offices: 1257 Cobblestone Way, Suite A, Woodstock, IL 60098 and 11 N Skokie Hwy, Lake Bluff, IL 60044. Phone (224) 220-3660. Email info@gshaservices.com. We install and service Generac generators across the northern and western Chicago suburbs; see the full service area by ZIP code. Contact us · Financing · All products and brands
GSHA Services, LTD is an independent authorized Generac dealer. Generac® is a registered trademark of Generac Power Systems, Inc.
Sources
- Generac Home Standby Generator, 10kW (model 7257) — https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-10kw-7257/ (accessed 2026-10-23)
- Generac Home Standby Generator, 28kW (model 7282): ratings, fuel pressure, Power Zone 200 controller, cellular Mobile Link, PWRcell and ecobee compatibility, 5-year limited warranty, most powerful air-cooled claim — https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-28kw-7282/ (accessed 2026-10-23)
- Generac Home Standby Generator, 28kW with Transfer Switch and ecobee by Generac Smart Thermostat Bundle (model 7329) — https://www.generac.com/residential-products/standby-generators/gaseous/standby-generator-28kw-7329/ (accessed 2026-10-23)
- Generac spec sheet, 10/14/18 kW air-cooled standby generator (models, output, current, sound, engines, 18-inch clearance, transfer switches, load management and cold-weather accessories, Mobile Link Cellular) — https://productmanuals.generac.com/api/manualfiles/G0072580/A0005151081/0 (accessed 2026-10-23)
- Generac spec sheet, 22-28 kW air-cooled standby generator — https://productmanuals.generac.com/api/manualfiles/G0072600/A0005151077/0 (accessed 2026-10-23)
- Generac Support: What Are the Available Mobile Link Subscription Plans — https://support.generac.com/articles/Knowledge/What-Are-the-Available-Mobile-Link-Subscription-Plans (accessed 2026-10-23)
- Generac Owner’s Manual, 60 Hz Air-Cooled Generators 10-26 kW, A0001846499 Rev. C (2023): installation qualifications, maintenance schedules, exercise cycle, registration and extended coverage — https://www.generac.com/globalassets/products/residential/standby-generators/owners-manual/g-10-26kw-60hz-standby-generator-owners-manual-en.pdf (accessed 2026-10-23)
- Census Reporter API, ACS 2024 5-year (2020-2024) tables B25040 house heating fuel and B25035 median year built, Boone, Cook, DuPage, Kane, Lake, McHenry and Will counties — https://api.censusreporter.org/1.0/data/show/acs2024_5yr?table_ids=B25035,B25040&geo_ids=05000US17007,05000US17031,05000US17043,05000US17089,05000US17097,05000US17111,05000US17197 (accessed 2026-10-23)
- GSHA Generac generators page (current sizes, basic installation and add-ons) — https://gshaservices.com/electrician-near-me/whole-house-generator-installation/generac-generators/ (accessed 2026-10-23)
- GSHA service area page (ZIP-code list) — https://gshaservices.com/about-gsha-services/service-area/ (accessed 2026-10-23)