Online Estimate

Schedule Now

CGa Gas Boiler Weil-McLain Series 2

Request a Price

  • Compact design saves valuable living space
  • Stainless steel burners for quieter ignition, longer life, and improved combustion
  • Gas fired water boiler with cast iron sections
  • Easily accessible controls, vertical flueways and top cleaning for easy and quick servicing
  • Up to 84% AFUE
SKU: CGa Category:
Financing Available

Description

CGa Gas Boiler Weil-McLain Series 2 is compact design saves valuable living space. Stainless steel burners for quieter ignition, longer life, and improved combustion. Gas fired water boiler with cast iron sections. Easily accessible controls, vertical flueways and top cleaning for easy and quick servicing. Up to 84% AFUE.

 

CGa Gas Boiler Weil-McLain Features:

  • Factory Tested
  • Two-Piece Top Jacket Panel
  • Insulated Extended S teel Jacket
  • Cast Iron Sections with Built-in Air Separator
  • Radiation Plates
  • Vertical Draft Hood
  • Automatic Vent Damper
  • Combination Gas Valve for 24 Volt
  • Wiring Harness
  • Non-Linting Pilot Burner
  • Stainless Steel Burners
  • Electrical Junction Box
  • Rollout Thermal Fuse Element
  • High-Limit Temperature Control
  • Circulator (when ordered) – Sizes 25–5: Taco 007e – Sizes 6–8: Taco 007
  • Spill Switch
  • 30 PSI ASME Relief Valve (boiler sections tested for 50 PSI working pressure)
  • Combination PressureTemperature Gauge
  • Drain Valve
  • Integrated Boiler Control Module with Intermittent Electronic Ignition System & Indicator/Diagnostic Lights
  • 40 VA Transformer
  • Plug-in Connector and Wiring

 

The control module responds to signals from the room thermostat and boiler limit circuit to operate the boiler circulator, pilot burner, gas valve and vent damper. When room thermostat calls for heat, the control module starts the system circulator and activates the vent damper (causing it to drive open). When the vent damper has opened completely, the control module opens the pilot valve and activates pilot ignition spark.

For natural gas, the control module allows up to 15 seconds to establish pilot flame. If flame is not sensed within 15 seconds, the control module will turn off the gas valve, flash the Flame light, and immediately start a new cycle. This will continue indefinitely until pilot flame is established or power is interrupted. Once pilot flame is proven, the control module opens the gas valve to allow main burner flame.

For propane gas, the control module allows up to 15 seconds to establish pilot flame. If flame is not sensed within 15 seconds, the control module will turn off the gas valve, flash the Flame light, wait 1 minute, then start a new cycle. If flame is still not sensed after the second trial, two more attempts are made with 5 minute and 60 minute wait periods in between. If flame is not sensed after 4 tries, control will lockout and flash all lights. Control must be manually reset to place back into service. Once pilot flame is proven, the control module opens the gas valve to allow main burner flame.

Additional information

Brand

Weil-McLain

Energy Efficiency

Up to 84% AFUE