Home Generator Error Codes & Alarms: Generac, KOHLER, Cummins and Briggs & Stratton
Every home standby generator has its own way of telling you something is wrong. It may be a red light, a flashing panel, a code on a display or an alert on your phone. This guide explains what those alarms and warnings mean in plain language. It also shows how each of the four major brands displays them, what is safe for you to check, and when to call for service.
- Authorized Generac dealer and authorized KOHLER dealer
- We install, service and repair Cummins and Briggs & Stratton home standby generators
- Serving Chicagoland & southeastern Wisconsin
What the lights and alarms on a home generator mean
Every brand uses the same small set of signals. There is a status light on the generator. There is a message on a display, either on the unit or on a panel inside your house. Many units can also send an alert to an app or by email. Examples are Generac Mobile Link, KOHLER OnCue Plus and the Cummins internet and email interface. The colors and exact words differ by brand, but the idea is the same.
Green or “Ready”
The generator is in automatic (standby) mode and utility power is present. On a Generac, the green light flashes while your house is running on generator power. On current Generac models it also flashes during the short countdown before the engine starts. A Briggs & Stratton in-home monitor blinks green during the weekly exercise run.
Yellow or flashing
A warning or a maintenance reminder. The generator can usually still run, but something should be looked at soon. A Generac yellow light comes on for a warning or when service is due (on current models it flashes). A Briggs & Stratton AUTO light blinks if the weekly exercise is not set or is turned off.
Red or “Action required”
Usually an alarm: the generator has stopped and will not start on its own until the alarm is cleared. But red does not always mean a shutdown. On a current Generac, solid red means the unit is set to OFF and flashing red means an alarm. On older Generac units the red light is on for either one. A Cummins in-home panel lights a red ACTION REQUIRED lamp when the unit has shut down or when maintenance is due. Check the display, panel or app to see which.
How each brand shows an alarm
| Brand | Where you see it | Alarm / shutdown | Warning or maintenance |
|---|---|---|---|
| Generac | Status lights on the side of the unit. The controller display under the lid on Evolution units, or the Mobile Link app on the newest units, which have no screen. | Red light (it flashes on current models). The alarm name shows on the display or in the app. Evolution controllers also show a four-digit code on the display (for example Low Oil Pressure 1300). | Yellow light (it flashes on current models). Messages such as Low Battery or Charger Missing AC. Maintenance: SERVICE A or SERVICE B on the Evolution display. Newer units show Schedule A, B or C in the Mobile Link app. |
| KOHLER | Current units: the RDC2 controller’s two-line display next to the OFF, AUTO and RUN buttons. OnCue Plus app or email/text alerts. | The unit stops, a fault message shows on the display, and the OFF light flashes quickly. | A warning message shows, but the unit keeps running. Warnings clear on their own once the cause is fixed. |
| Cummins | The in-home operator panel (utility and generator status lamps plus a screen). A status light on the control switch inside the generator. | The red ACTION REQUIRED lamp comes on. A FAULT screen shows a short description and a fault code number. The light on the unit blinks a pattern. | Warning events (for example low battery or charger failure). A Maintenance Due screen that does not time out on its own. |
| Briggs & Stratton | Current 15–20 kW units: a digital display on the control panel, the AUTO light and the wireless in-home monitor. | A service code description scrolls across the display (for example Low Oil Pressure). Codes 1–8 also blink the light in a pattern. | Not every service code stops the unit. The AUTO light blinks if the exercise cycle is not set or is turned off. |
Exact light patterns and wording depend on the model, controller and firmware. Your owner’s manual has the full chart for your unit.
Alarm vs. warning vs. maintenance reminder
The brands use different words, but most messages fall into three groups.
Alarm Unit stopped
Generac calls it an alarm, KOHLER a shutdown and Cummins a fault. The controller stopped the engine to protect it. Examples are low oil pressure, high engine temperature or too many failed start attempts. The generator will not start in an outage until the alarm is cleared. Briggs & Stratton shows problems as service codes. Many of them, such as Low Oil Pressure, shut the unit down. Some do not.
Warning Needs attention
The generator keeps running or stays ready, but something is off. Examples are a low battery, a battery charger that is not getting power, or a lost link to the transfer switch. That is the box that moves your house from utility power to generator power. An ignored warning, such as a low battery, can lead to a failed start later.
Maintenance reminder Service due
The controller keeps track of run hours and time. When an oil change or inspection is due, Generac shows SERVICE A or B on the display. Newer Generac units show Schedule A, B or C in the Mobile Link app. Cummins shows a Maintenance Due screen that does not time out on its own. Book a generator tune-up to take care of it.
One important difference between brands: what happens to your house. On current Briggs & Stratton 15–20 kW units, an active service code sends the transfer switch back to utility power, if the utility is on. On a Cummins RS unit, STANDBY turns off after a fault shutdown or after a manual start or stop. It must be turned back on at the in-home panel, or the generator will not start on its own. On Generac and KOHLER units, the generator stays off after a shutdown until the alarm is cleared. After any shutdown, your home has no backup power until the generator is back in automatic mode.
Find your brand’s error codes
Each brand has its own page with the full list of codes and messages, what they mean, and what you can safely do. Pick yours below.
Generac error codes
Controllers: Evolution 1.0 and 2.0, the newest PowerZone 200, and older Nexus units. Evolution shows the alarm name and a four-digit code on the controller display. Examples are Overcrank (1100), Overspeed (1200), Low Oil Pressure (1300) and High Temperature (1400). Nexus shows the alarm name without a number.
To clear on Evolution: press OFF, then ENTER, then AUTO. On the newest units: press and hold OFF for at least three seconds until the red light goes solid, then press AUTO. If the alarm comes back, call.
Generac generator error codes →
GSHA Services is an authorized Generac dealer.
KOHLER error codes
Current KOHLER home units (RDC2 or DC2 controller): warnings show a message but do not stop the unit. Shutdowns stop the engine, show a fault message and flash the OFF light. OnCue Plus can email or text you when a fault happens.
To clear: fix the cause, press OFF to reset the controller, then press AUTO. If the fault comes back, call. Older KOHLER units with the ADC-RES controller work differently, so check your owner’s manual.
KOHLER generator error codes →
GSHA Services is an authorized KOHLER dealer.
Cummins error codes
Models: RS13A and RS14–RS20 (GSBA/GSBB) home standby units. Most of what you see is on the in-home operator panel. After a shutdown, the screen shows a short fault description and a fault code number. Examples are Code 2 Low Oil Pressure, Code 4 Overcrank and Code 46 Overload.
To clear: press BACK on the panel to reset the fault. Then press STANDBY ON/OFF, select ON and press BACK. This lets the unit start on its own again. If the fault comes back, call.
Cummins generator error codes →
We install, service and repair Cummins home standby generators.
Briggs & Stratton error codes
Current 15–20 kW units with the OFF, MANUAL and AUTO button panel: problems scroll across the display as numbered service codes (1–16). Examples are 1 Low Battery Voltage, 2 Low Oil Pressure, 4 Engine Does Not Start and 8 Transfer Switch Fault.
To clear: press and hold OFF until the code stops scrolling. Then hold OFF again for at least 7 seconds, until the display turns off. Leave it off for at least 30 seconds. Fix the cause, then press and hold AUTO. If the code comes back, call. Older units use a two-position AUTO/OFF system switch and show “FC” fault codes, so check your owner’s manual.
Briggs & Stratton generator error codes →
We install, service and repair Briggs & Stratton home standby generators.
Not sure what brand or model you have?
The brand name is usually printed on the outside of the enclosure. The model and serial number are on a data plate (a metal plate or sticker) on the unit. Manufacturers ask for these numbers before parts or service can be arranged, so have them ready when you call. The easiest place to find them is your installation paperwork, your warranty registration or your installer’s photos. We can also read them on the service visit. Just tell us the brand and what the display or app says.
If you do look on the unit, set it to OFF first. Do not remove any panels, screws or covers. Here is where each brand puts the label:
- Generac: the data decal is under the lid, on the inside partition to the left of the controls. It lists the model, serial number, production date, voltage and amps. Your paperwork is easier.
- KOHLER: a nameplate on the generator lists the model, specification and serial numbers. The service views in your owner’s manual show where it is on your model.
- Cummins: the generator set nameplate lists the model, spec and serial numbers. Cummins notes that every character matters when ordering parts.
- Briggs & Stratton: on current units, the data label is inside the battery access compartment, behind a panel. Use your paperwork instead, and let the technician read the label.
Five things to do for any generator alarm
- Write down exactly what it says. Take a photo of the display, the in-home panel or the app screen, including any code number. Note when it happened and whether the power was out. A photo helps the technician bring the right parts.
- Do the safe checks. With the unit in OFF, go through the “Safe for you to do” list below. Common causes are blocked vents, a closed gas valve, an empty propane tank, a breaker that is off, or too many large appliances on.
- Clear the alarm once. Use your brand’s button sequence from the brand cards above or your owner’s manual. Never jumper, bypass or disconnect a safety switch. Never keep clearing the same alarm.
- Confirm the generator is back in standby. Look for the green or AUTO light, a “Generator Ready” or “Standby” message, or the app status. Until it is back in automatic mode, your home has no backup power for the next outage.
- If the same alarm comes back, stop and call. KOHLER says to find and correct the cause before resetting, and to contact an authorized dealer when needed. Briggs & Stratton notes that the same service code returns until the problem is corrected. Generac says to contact a dealer if the alarm comes back. Clearing it again will not fix it.
Safe checks you can do — and what to leave to a pro
Safe for you to do (unit in OFF)
- Look for leaves, snow, nests or plants blocking the enclosure vents, and clear them
- Check that the gas valve to the generator is open and the propane tank is not empty
- If you can see your generator’s own circuit breaker without tools, check that it is ON. Never remove screws or covers to reach it.
- Check whether an emergency stop switch was pressed. Reset it per your owner’s manual only if you know who pressed it and why, and nothing is wrong. Otherwise, call.
- Open the app or in-home panel and read the fault message and battery status
- Turn off large loads (central air, range, dryer, well pump) before restarting
- Press OFF, then AUTO (or your brand’s sequence) — once
Leave these to a technician
- Removing panels, screws or covers, replacing fuses or touching any wiring
- Gas line, regulator or fuel pressure work
- Oil pressure switch, temperature switch and sensor tests
- Transfer switch internals and communication wiring
- Battery, charger and alternator testing
- Firmware updates and controller settings
- Any alarm that repeats after one reset
When to call for generator service
- The same alarm comes back after you cleared it once.
- An alarm for low oil pressure, high engine temperature or a transfer switch problem.
- An overspeed alarm (the engine ran too fast) or an overcrank alarm (the engine cranked but would not start).
- An overvoltage or undervoltage alarm (power output too high or too low).
- The generator did not start during an outage, or it started but your house never switched over to generator power.
- Your lights are out while utility power is on.
- A battery or charger warning does not clear on its own.
- A maintenance reminder is showing, or it has been more than a year since the last service.
- You hear unusual noises, see smoke or leaking oil, or smell fuel near the unit.
GSHA Services is an authorized Generac dealer and an authorized KOHLER dealer. We also install, service and repair Cummins and Briggs & Stratton home standby generators. Regular maintenance can help catch problems before a storm. Learn more about our generator repair, generator maintenance, whole-house generator installation and KOHLER generator service.
Request generator service or repair
Tell us the brand, the alarm or code you are seeing, the model number if you have it, and the best time to reach you. Our team will contact you to schedule a visit. For an urgent problem during an outage, please call (224) 220-3660.
Generator service area
GSHA Services is based in Woodstock, IL and services home standby generators across Chicagoland, including McHenry County and Lake County, and southeastern Wisconsin. Not sure if we cover your address? Call us or send the form above.
Frequently asked questions about generator alarms
What does a red light on my home generator mean?
Usually an alarm: the generator has shut itself down and will not start until the alarm is cleared. But red can mean other things. On a Generac, the red light also comes on when the unit is simply set to OFF. On a Cummins in-home panel, the red ACTION REQUIRED lamp can also mean maintenance is due. Check the display, panel or app to see which it is. Then fix any obvious cause, clear an alarm once, and call if it comes back.
Is a warning the same as an alarm?
No. A warning means the generator can still run, but something needs attention soon, such as a low battery or a charger with no power. An alarm (Generac), shutdown (KOHLER) or fault shutdown (Cummins) means the generator has stopped to protect itself. It will not start on its own until the alarm is cleared. Briggs & Stratton shows problems as service codes. Many of them shut the unit down, but not all.
Can I reset my generator myself?
Yes, once. Fix any obvious cause first. Then use your brand’s clear sequence, shown on the brand cards above, on each brand’s error code page and in your owner’s manual. Never jumper or bypass a safety switch. If the same alarm comes back, stop and call for service.
Will my house still have power if the generator shows an alarm?
Usually, yes. If utility power is on and the transfer switch is working, your house stays on utility power. If your lights are out while the utility is on, call right away. The bigger problem is the next outage. After a shutdown alarm, the generator will not start on its own until the alarm is cleared and the unit is back in automatic mode.
How do I find my generator’s model and serial number?
Check your installation paperwork or warranty registration first. On the unit, the numbers are on a data plate. The section above shows where each brand puts it. Set the unit to OFF before you look, and do not remove any panels or covers. We can also read the plate on the service visit.
Related generator pages
Generac® and Mobile Link® are trademarks of Generac Power Systems, Inc. KOHLER® and OnCue® are trademarks of Kohler Co.; KOHLER generators are a Rehlko business. Cummins® is a trademark of Cummins Inc. Briggs & Stratton® is a trademark of Briggs & Stratton, LLC. GSHA Services, LTD is an authorized Generac dealer and an authorized KOHLER dealer. This page is general guidance for homeowners; always follow the safety instructions in your owner’s manual and on the unit.