Generac Generator Error Codes & Alarms: What They Mean and What to Do
Is your Generac home standby generator showing a red or yellow light, an alarm on the display, or a message in the Mobile Link app? This guide explains the most common Generac alarm and error codes in plain language, which simple checks are safe for you to do, and when it is time to call a Generac service technician.
- Authorized Generac dealer
- Generac-trained technicians
- Service, repair & maintenance on all Generac home standby models
- Serving Chicagoland & southeastern Wisconsin
What the red, yellow and green lights on a Generac generator mean
Most Generac air-cooled home standby generators have status lights you can see from outside the unit, and the same status shows up in the Mobile Link app. Here is what the colors generally mean:
Green light
The generator is in AUTO, utility power is present and the unit is ready. A flashing green light usually means the power went out and the generator is counting down to start, or it is running and powering your home.
Yellow light
A warning or maintenance reminder. The generator can usually still run, but something needs attention soon — for example a battery or charger warning, or scheduled maintenance is due.
Red light
An alarm. The generator has shut down or will not start until the problem is fixed and the alarm is cleared. A red light can also mean the unit is in OFF or the emergency shutdown switch was pressed.
Exact light patterns vary by model and controller (Nexus, Evolution or PowerZone). Your owner’s manual has the full chart for your unit. Read more: Generac red, yellow and green lights explained.
Alarms vs. warnings vs. maintenance reminders
Alarm Red – unit stopped
A serious condition that stops the generator to protect the engine, the alternator or your home. Your home is not protected from outages until the alarm is fixed and cleared.
Warning Yellow – needs attention
A problem that has not stopped the generator yet, such as a weak battery or a battery charger with no power. If it is ignored, many warnings turn into a no-start during the next outage.
Maintenance reminder Yellow
The controller counts run hours and time. When a service interval is due (Generac lists Schedule A and Schedule B), it reminds you. Book a generator tune-up and we reset the reminder after the service.
Generac generator error code list
Generac controllers show an alarm name and a 4-digit code (for example “Low Oil Pressure – 1300”). The same code appears in the Mobile Link app. Find your code below. Codes apply to Generac air-cooled home standby generators with Evolution and PowerZone controllers; older Nexus units show the alarm name without a number.
| Code | Alarm shown | What it means (in plain words) | What you can do |
|---|---|---|---|
| 1100 / 1101 | Overcrank Alarm | The engine cranked several times but did not start. The generator stops trying to protect the starter. Common causes: fuel supply problem (gas valve off, propane tank low), weak battery, ignition or starter trouble. | Make sure the gas valve to the generator is open and, for propane, the tank has fuel. Then call us — do not keep resetting. |
| 1200–1207 | Overspeed Alarm | The engine ran too fast. This is usually a fuel/throttle control problem (stepper motor or mixer). | Call for service. Running at overspeed can damage the generator and your appliances. |
| 1300 | Low Oil Pressure Alarm | Oil pressure dropped too low, so the engine shut down to protect itself. Often the oil level is low; it can also be the oil pressure switch or wiring. | With the unit in OFF, check the oil level on the dipstick if you are comfortable. If it is low, do not run it — call us. Low oil can mean a leak or engine wear. |
| 1400 / 1401 | High Temperature Alarm | The engine got too hot. Most often air can’t flow through the enclosure — leaves, snow, grass clippings, nests or plants blocking the vents. | Clear anything blocking the air intake and exhaust sides of the enclosure (keep the recommended clearances). If it returns, call us. |
| 1500–1521 | RPM Sensor Loss Alarm | The controller lost the engine speed signal while cranking or running. Causes include ignition problems, starter problems, air in the gas line or dirty fuel. | Call for service. |
| 1600–1603 | Underspeed Alarm | The engine could not reach or hold normal speed. Often the generator is overloaded or the fuel supply is too small or low (propane tank, gas pressure, undersized gas line). | Check propane level. Turn off large loads you don’t need during outages. Call us if it repeats. |
| 1800 | Overvoltage Alarm | Generator output voltage was too high. The unit shuts down to protect your electronics. | Call for service. |
| 1900–1916 | Undervoltage Alarm | Output voltage was too low — often from a sudden large load, loose wiring or an alternator/excitation problem. | Call for service. |
| 2098 / 2099 | Wiring Error / Transfer Wire Warning Alarm | The control wires between the generator and the transfer switch are miswired, damaged or not getting the right voltage. Common after new installs or after work on the property (digging, landscaping). | Call for service. A licensed technician must check the wiring. |
| 2100–2103 | Overload – Remove Load Alarm | Your home asked for more power than the generator can supply — for example central AC, an electric range, a dryer and a well pump starting at once. | Turn off large appliances, then clear the alarm. If it keeps happening, ask us about load management modules or a larger generator. |
| 2299 | Undervoltage Overload Alarm | The generator tried to start with a large load already connected and couldn’t reach normal voltage. | Reduce loads and call us so we can check the transfer switch and load shedding. |
| 2399 | Stepper Overcurrent Alarm | A fault in the throttle (stepper) motor circuit that controls engine speed. | Call for service. |
| 2400 | Fuse Problem Alarm | The controller’s 7.5-amp fuse is blown or missing. A blown fuse usually means there is a short somewhere. | Call for service. Replacing the fuse without finding the cause often blows it again. |
| 2800 | Auxiliary Shutdown Alarm | The external emergency shutdown circuit is open — most often the red emergency stop switch on the outside of the unit was pressed. | Check whether the emergency shutdown switch was pressed and reset it per your owner’s manual. If it wasn’t pressed, call us. |
| — | Model Ident Problem Alarm | The controller cannot read the model ID. Usually seen after a controller replacement or harness work. | Call for service. |
Code meanings above summarize Generac service information for air-cooled home standby generators. Your exact model, controller and firmware may show slightly different names. Liquid-cooled and older models can use other codes — call us with your model and serial number from the data plate.
Battery and battery charger messages
Battery messages are the most common reason a Generac won’t start during an outage. They are usually warnings (yellow), but you should not ignore them.
| Code | Message | What it means | What you can do |
|---|---|---|---|
| — | Low Battery Warning | Battery voltage has stayed low. | Schedule a battery test. Most standby batteries need replacing every few years. |
| 2760 | Battery Problem Warning | After a full charging cycle, the battery still isn’t healthy — it won’t hold a charge or is drawing too much current. | The battery most likely needs replacing. Call us. |
| 2770 | Charger Warning Warning | The battery charger is not charging correctly. | Call us to test the battery and the charger. |
| 2780 | Charger Missing AC Warning | The charger inside the generator is not getting 120-volt power, so the battery isn’t being charged. Common after a tripped breaker or on new installs before utility power is connected. | Check the breaker labeled for the generator/transfer switch in your panel. If it isn’t tripped, call us. |
| — | Inspect Battery Reminder | A reminder to have the battery checked, usually as part of routine service. | Include a battery test in your next maintenance visit. |
Other messages you might see
- No Rotation Warning – the controller told the engine to crank, but it didn’t turn. Often a battery, starter or wiring problem.
- Release Keys / Test Mode – a button on the control panel is held down or stuck. Make sure nothing is pressing on the panel.
- Service Schedule A / B – routine maintenance is due. Schedule a tune-up.
- Low fuel pressure (Mobile Link) – the generator isn’t getting enough gas. Check your propane tank; for natural gas, the gas line or meter may be undersized.
How to clear a Generac alarm safely
- Write down the alarm name and code (or take a photo of the display or the Mobile Link screen). This helps our technician arrive with the right parts.
- Fix the obvious cause first — clear debris from vents, open the gas valve, turn off big loads, or reset the emergency stop switch.
- Press OFF, then AUTO on the control panel to clear the alarm. The red light should go out and the green light should come on.
- Clear it only once. If the same alarm comes back, stop and call a Generac technician. Repeated resets can damage the engine or starter.
Safe checks you can do before you call
Look at the outside
- Leaves, snow, grass or nests blocking the vents
- Plants or objects too close to the unit
- Signs of animals chewing wires
- Oil or fuel leaks under the unit
Check fuel and power
- Gas shut-off valve to the generator is open
- Propane tank has enough fuel
- Generator breaker in your electrical panel isn’t tripped
- Emergency stop switch wasn’t pressed
Check the app
- Open Mobile Link to see the alarm and history
- Confirm your weekly exercise is running
- Note when the alarm first appeared
Leave these to a pro
- Opening panels, fuses or wiring
- Gas line or regulator work
- Transfer switch problems
- Any alarm that repeats
When to call a Generac service technician
- The same alarm comes back after you cleared it once.
- You see Low Oil Pressure (1300), Overspeed (1200s), Overvoltage (1800), Undervoltage (1900s), Wiring Error (2098/2099) or Fuse Problem (2400).
- The generator didn’t start during an outage or didn’t transfer power to your home.
- A battery or charger warning won’t go away.
- You hear unusual noises, see smoke, or smell fuel.
- Your generator is overdue for maintenance or it’s been more than a year since the last service.
As an authorized Generac dealer, GSHA Services diagnoses and repairs Generac home standby generators and automatic transfer switches using Generac service procedures and genuine parts, handles warranty repairs on qualifying units, and performs annual maintenance so alarms don’t surprise you during the next storm. We also service KOHLER and other brands. Learn more about our generator repair, generator maintenance and Generac generator installation.
Request Generac service or repair
Tell us your generator’s alarm or error code, the model (from the data plate if you have it) and the best time to reach you. Our team will contact you to schedule a visit. For an urgent problem during an outage, please call (224) 220-3660.
Generac service area
GSHA Services is based in Woodstock, IL and services Generac generators across Chicagoland, including McHenry County and Lake County, and southeastern Wisconsin. Not sure if we cover your address? Call us or send the form above.
Generac alarm and error guides
Each guide explains one alarm in plain language: what it means, why it happens, what you can safely do and what our technician checks.
Other brands: KOHLER fault codes · Cummins fault codes · Briggs & Stratton fault codes · All brands
Frequently asked questions about Generac error codes
Why is the red light on my Generac generator on?
A red light means an alarm has stopped the generator, or the unit is in OFF. Check the display or the Mobile Link app for the alarm name and code, fix the simple cause if there is one, then press OFF and AUTO once. If the red light comes back, call a Generac technician.
What does a yellow light on a Generac generator mean?
A yellow light is a warning or a maintenance reminder. The generator usually can still run, but the problem — often the battery, the battery charger or maintenance that’s due — should be taken care of soon.
What does Generac error code 1300 mean?
Code 1300 is Low Oil Pressure. The engine shut down because oil pressure dropped too low. Check the oil level with the unit in OFF. Do not keep restarting the generator; call for service to find out why the oil pressure dropped.
What does Generac code 2800 mean?
Code 2800 is Auxiliary Shutdown. The emergency shutdown circuit is open, usually because the external emergency stop switch was pressed. Reset the switch according to your owner’s manual, then clear the alarm. If the switch wasn’t pressed, call us.
What does “Charger Missing AC” (2780) mean?
The generator’s battery charger isn’t receiving 120-volt power, so the battery isn’t being charged. Check whether the generator breaker in your electrical panel is tripped. If it isn’t, a technician needs to check the circuit.
How do I reset my Generac generator after an alarm?
After fixing the cause, press OFF and then AUTO on the control panel. Only reset once — if the same alarm returns, the problem needs a technician.
Can I still use my generator with an alarm showing?
No. With an active alarm the generator won’t start automatically during an outage. Warnings (yellow) usually allow the unit to run, but they should be fixed soon so the generator is ready when you need it.
Do you repair Generac generators under warranty?